FS1A Safety Controller
No programming required.
Configuration complete by turning on a logic switch.
Features & Benefits
- A safety circuit can be configured easily just by selecting a logic from pre-programmed logics.
- Mode selection, partial/entire stop can be achieved just by selecting a logic.
- One SafetyOne module can connect with various safety inputs such as emergency stop switches and light curtains.
- The status of safety I/Os and the SafetyOne errors can be monitored.
- IEC 61508 safety integrity level 3, ISO 13849-1 performance level e, and category 4 compliant.
HR6S Series Safety Relay Modules
Advanced Diagnostics & Output Functions
Improve productivity with predictive maintenance of safety systems.
Functions & Benefits
- Predictive Maintenance: Not only diagnostic results, but detailed information regarding safety-related parts such as input/output status can be acquired to prevent unintended stops
- Connect to various input devices: Dials are used to select input devices and start functions to enable safety measures for a wide variety of machines and allows standardization of the relay module.
- Setting a start function: Select from 8 types of start functions without changing the wiring. Automatic and manual operation can be selected as well as “startuptest”, which requires monitoring, cross-circuit detection, and pre-start inspection.
- Setting an application function: Set up to 7 types of input devices, such as emergency stop switches, interlock switches, light curtains, RFID devices, magnet switches, proximity switches, two-hand control switches, and pressure-sensitive switches.
- LED Display for viewing status at a glance: The LED indicators display approximately 20 different states by steady or flash light, or by combining. When an error occurs, its location is indicated, allowing maintenance to be performed immediately.
- Delay function: By using the dials to set a combination of a coefficient from 0 to0.9 and a magnification from 1x to 1000x, time limit can be set in the range of 0 to 900 seconds. Also, the external input can be used to cancel the off-delay and immediately cut off the output. Expanded (*1) output can beset to either instantaneous or delay. The delay output used to unlock the solenoid is compatible with category 1 and PLc.
- Screw or Push-in Terminal Block: Choose from two types: a conventional screw terminal block or a highly-reliable push-in terminal block that saves wiring time. Both are removable and easy to maintain.
HR5S Series Safety Relay Modules
Safety measures for low risk machines
The first category 2 safety relay module in the industry.
Functions & Benefits
- The first category 2safety relay module in the industry.
- Ideal for low-risk machines.
- Safety with non-redundant safety circuit.
- Push-in terminals save installation labor and prevent loosening of wires.
- Slim body save control panel space.
HR1S-AC Safety Relay Modules
Transistor output provided
Removable terminal block with fault diagnosis function.
Functions & Benefits
- Removable terminal block (HR1S-AC5121P) allows for easy module replacement.
- Fault diagnosis function with dual safety circuits.
- Internal relay operations can be monitored with LED indicator.
- Finger-safe protection
- 35-mm-wide DIN rail mounting
- EN, IEC compliant.
- TUV NORD approved.
- UL listed, CSA approved.
HR1S-AF Safety Relay Modules
Removable terminal block with fault diagnosis function
Small and high function (welding detection of start switch).
Features & Benefits
- Removable terminal block (HR1S-AC5121P) allows for easy module replacement.
- Fault diagnosis function with dual safety circuits.
- Internal relay operations can be monitored with LED indicator.
- Finger-safe protection
- 35-mm-wide DIN rail mounting
- EN, IEC compliant.
- TUV NORD approved.
- UL listed, CSA approved.
HR1S-AK Safety Relay Modules
Four transistor outputs
Finger safe protection with fault diagnosis function.
Features & Benefits
- Removable terminal block (HR1S-AC5121P) allows for easy module replacement.
- Can be connected to light curtain.
- Fault diagnosis function with dual safety circuits.
- Internal relay operations can be monitored with LED indicator.
- Finger-safe protection
- 35-mm-wide DIN rail mounting
- EN, IEC compliant.
- TUV NORD approved.
- UL listed, CSA approved.
HR1S-ATE Safety Relay Modules
New compact safety relay modules.
Size is reduced by 50% from conventional models. Plug-in terminal structure enables simple wiring.
Features & Benefits
- EN ISO 13849-1 performance level e, safety category 4 compliant, and EN 62061 safety integrity level 3.
- Integrated and removable terminal styles available.
- Compact design: 45 mm in width.
- Time delay outputs: 3NO
- Auxiliary output enables power supply monitoring, inputs (2 channels), and a time delay output.
- Environmentally friendly, RoHs directive compliant.
- UL Listed, CSA certified, TÜV NORD approved.
HR1S-DMB/DME Safety Relay Modules
Removable terminal block with IP67 degree of protection
Safety relay module for non-contact interlock switch.
Features & Benefits
- 1NO-1NC safety input type, such as magnetic coded safety switches
- Fault diagnosis function with dual safety circuits.
- Internal relay operations can be monitored with LED Indicator.
- Finger-safe protection
- 22.5 or 45mm wide, 35mm DIN rail mounting
- EN ISO 13849-1 PLe, Safety Cat 4 compliant, and EN 62061 SIL 3
- UL listed, CSA certified, TÜV NORD approved
HR2S-301P/HR2S-301N Safety Relay Modules
Safety Category 4, PLe
Compact design and maintenance improvements for outstanding usability!
Features & Benefits
- Compliant with EN ISO 13849-1 Performance level (PL) e, Category 4.
- Compliant with categories 2 (type 2) and 4 (type 4) when used with a safety light curtain.
- Spring terminals enable easy wiring.
- The terminal cover does not close if the terminal is not fully inserted into the module.
- IP20 (terminal) / IP40 (housing)
HR2S-322N-T075/T15/T30 Safety Relay Modules
Simple wiring procedure with removable terminal block
Time delay output compliant to category 4.
Features & Benefits
- Compliant with EN ISO 13849-1 Performance level (PL) e, Category 4.
- Compliant with categories 2 (type 2) and 4 (type 4) when used with a safety light curtain.
- Spring terminals enable easy wiring.
- The terminal cover does not close if the terminal is not fully inserted into the module.
- IP20 (terminal) / IP40 (housing)
Type
Name
Downloads
FS1A Safety Controller Brochure
HR Series Safety Relay Modules Catalog
HR5S Series Safety Relay Modules Catalog